Product Features | ||
Medical & ITE safety approvals | ||
2MOPP input to output isolation | ||
Leakage current≤ 100μA | ||
Standby power ≤0.3W | ||
9V to 24V outputs, up to 48W | ||
3 types of AC inlet | ||
Technical Data | ||
Input Voltage Range: 90~264VAC | ||
Input Current:1.1A at 90VAC | ||
Output voltage Tolerance:±5% | ||
Environmental Requirements | ||
Operating Temperature: 0~40℃ | ||
Storage Temperature: -20~60℃ | ||
Operating Humidity:10~90%RH, non-condensing | ||
Storage Humidity: 5~90%RH | ||
Operating Altitude: 3,048 M | ||
Safety Approvals | ||
Safety aAgency/Mark | Medical | I.T.E |
CB | IEC60601-1 | IEC60950-1 |
UL | ANSI/AAMI ES60601-1 | - |
CAN/CSA C22.2 NO.60601-1 | ||
TUV-SUD/Mark | EN60601-1 | - |
TUV-SUD/GS | - | EN60950-1 |
CCC | - | GB4943.1(For Class I only) |
PSE | - | J60950-1(For UE48-120300SPA1 only) |
CE | - | EN60950 |
FCC | - | FCC PART 15 |
Mechanical Details | ||
121(L)*30.8(W)*50(H)mm | ||
Applications: | ||
Medical Device and ITE Equipment |
Models & Ratings | |||||||
Model No. | Voltage (V) | Current (A) | Ripple & Noise (Max: mV) PK-PK | Voltage tolerance | Line& Load Regulation | Efficiency (Average) Min | Start Up delay |
9.0-12.0 | 0.01-4.02 | 200 | ±5% | 88.62% | ≤3S | ||
12.1-13.0 | 0.01-3.70 | 200 | ±5% | 88.61% | ≤3S | ||
13.1-14.0 | 0.01-3.43 | 200 | ±5% | 88.60% | ≤3S | ||
14.1-15.0 | 0.01-3.20 | 200 | ±5% | 88.59% | ≤3S | ||
15.1-16.0 | 0.01-3.00 | 200 | ±5% | 88.59% | ≤3S | ||
UE48-XXXYYYSPAZ | 16.1-17.0 | 0.01-2.83 | 200 | ±5% | Line:±1% | 88.61% | ≤3S |
17.1-18.0 | 0.01-2.67 | 200 | ±5% | Load: ±5% | 88.60% | ≤3S | |
18.1-19.0 | 0.01-2.53 | 200 | ±5% | 88.60% | ≤3S | ||
19.1-20.0 | 0.01-2.40 | 200 | ±5% | 88.59% | ≤3S | ||
20.1-21.0 | 0.01-2.29 | 200 | ±5% | 88.61% | ≤3S | ||
21.1-22.0 | 0.01-2.19 | 200 | ±5% | 88.62% | ≤3S | ||
22.1-23.0 | 0.01-2.09 | 200 | ±5% | 88.60% | ≤3S | ||
23.1-24.0 | 0.01-2.01 | 200 | ±5% | 88.62% | ≤3S |