Product Features | |
Lamp safety approvals, Medical & ITE safety meet | |
2 MOPP input to output isolation | |
DOE Efficiercy Level VI | |
CoC V5 Tier 2(2016) | |
Leakage current ≤ 100μA | |
≤ 0.15W standby power | |
11V to 48V outputs, up to 200W | |
Up to 5,000m operating altitude | |
4 types of AC inlet | |
Meet 4KV surge immunity IEC61000-4-5 |
Models & Ratings | ||||||||
Model Number | Voltage(*1) | Current | Rated | Ripple & Noise | Voltage | Line & Load | Efficiency | Start Up |
Power | (max)(*2) | Tolerance | Regulation | (Average) | Delay | |||
UES200-XXXYYYSPA1/ SPA2/ SPA3/ SPA4 | 11.0-12.0 | 0.01-15.0 | 180W | 150mVpk-pk | ±5% | Line: ±1% Load: ±5% | 89.00% | ≤3s |
12.1-13.0 | 0.01-14.0 | 182W | 150mVpk-pk | ±5% | 89.00% | ≤3s | ||
13.1-14.0 | 0.01-13.5 | 190W | 150mVpk-pk | ±5% | 89.00% | ≤3s | ||
14.1-15.0 | 0.01-13.3 | 200W | 150mVpk-pk | ±5% | 89.00% | ≤3s | ||
15.1-16.0 | 0.01-12.5 | 200W | 180mVpk-pk | ±5% | 89.00% | ≤3s | ||
16.1-17.0 | 0.01-11.7 | 200W | 180mVpk-pk | ±5% | 89.00% | ≤3s | ||
17.1-18.0 | 0.01-11.1 | 200W | 180mVpk-pk | ±5% | 89.00% | ≤3s | ||
18.1-19.0 | 0.01-10.5 | 200W | 180mVpk-pk | ±5% | 89.00% | ≤3s | ||
19.1-20.0 | 0.01-10.0 | 200W | 200mVpk-pk | ±5% | 89.00% | ≤3s | ||
20.1-21.0 | 0.01-9.52 | 200W | 200mVpk-pk | ±5% | 89.00% | ≤3s | ||
21.1-22.0 | 0.01-9.09 | 200W | 200mVpk-pk | ±5% | 89.00% | ≤3s | ||
22.1-23.0 | 0.01-8.69 | 200W | 200mVpk-pk | ±5% | 89.00% | ≤3s | ||
23.1-24.0 | 0.01-8.33 | 200W | 240mVpk-pk | ±5% | 89.00% | ≤3s | ||
24.1-25.0 | 0.01-8.00 | 200W | 240mVpk-pk | ±5% | 89.00% | ≤3s | ||
25.1-26.0 | 0.01-7.69 | 200W | 240mVpk-pk | ±5% | 89.00% | ≤3s | ||
26.1-27.0 | 0.01-7.40 | 200W | 240mVpk-pk | ±5% | 89.00% | ≤3s | ||
27.1-28.0 | 0.01-7.14 | 200W | 300mVpk-pk | ±5% | 89.00% | ≤3s | ||
28.1-29.0 | 0.01-6.89 | 200W | 300mVpk-pk | ±5% | 89.00% | ≤3s | ||
29.1-30.0 | 0.01-6.66 | 200W | 300mVpk-pk | ±5% | 89.00% | ≤3s | ||
30.1-31.0 | 0.01-6.45 | 200W | 300mVpk-pk | ±5% | 89.00% | ≤3s | ||
31.1-32.0 | 0.01-6.25 | 200W | 300mVpk-pk | ±5% | 89.00% | ≤3s | ||
32.1-33.0 | 0.01-6.06 | 200W | 360mVpk-pk | ±5% | 89.00% | ≤3s | ||
33.1-34.0 | 0.01-5.88 | 200W | 360mVpk-pk | ±5% | 89.00% | ≤3s | ||
34.1-35.0 | 0.01-5.71 | 200W | 360mVpk-pk | ±5% | 89.00% | ≤3s | ||
35.1-36.0 | 0.01-5.55 | 200W | 360mVpk-pk | ±5% | 89.00% | ≤3s | ||
36.1-37.0 | 0.01-5.40 | 200W | 360mVpk-pk | ±5% | 89.00% | ≤3s | ||
37.1-38.0 | 0.01-5.26 | 200W | 360mVpk-pk | ±5% | 89.00% | ≤3s | ||
38.1-39.0 | 0.01-5.12 | 200W | 360mVpk-pk | ±5% | 89.00% | ≤3s | ||
39.1-40.0 | 0.01-5.00 | 200W | 360mVpk-pk | ±5% | 89.00% | ≤3s | ||
40.1-41.0 | 0.01-4.87 | 200W | 480mVpk-pk | ±5% | 89.00% | ≤3s | ||
41.1-42.0 | 0.01-4.76 | 200W | 480mVpk-pk | ±5% | 89.00% | ≤3s | ||
42.1-43.0 | 0.01-4.65 | 200W | 480mVpk-pk | ±5% | 89.00% | ≤3s | ||
43.1-44.0 | 0.01-4.54 | 200W | 480mVpk-pk | ±5% | 89.00% | ≤3s | ||
44.1-45.0 | 0.01-4.44 | 200W | 480mVpk-pk | ±5% | 89.00% | ≤3s | ||
45.1-46.0 | 0.01-4.34 | 200W | 480mVpk-pk | ±5% | 89.00% | ≤3s | ||
46.1-47.0 | 0.01-4.25 | 200W | 480mVpk-pk | ±5% | 89.00% | ≤3s | ||
47.1-48.0 | 0.01-4.16 | 200W | 480mVpk-pk | ±5% | 89.00% | ≤3s |
Input | |
Input Voltage Range | 90-264VAC |
Frequency Range | 47-63Hz |
Input Current | 2.5A at 90VAC |
Inrush Current | 120A max at 240VAC cold start |
Touch Leakage Current | Class I & Class II ≤ 100μA at 264VAC |
Environmental | |
Operating Temperature | -20℃ to 40℃ |
Storage Temperature | -20℃ to 60℃ |
Operating Humidity | 10% to 90% RH, non-condensing |
Storage Humidity | 5% to 90% RH |
Operating Altitude | 5,000m |
Protection | |
Overload | 120-170% rated output power, auto recovery |
Over Voltage | 120-150% rated output voltage input to reset |
Short Circuit | Trip and restart (hiccup mode) |
Safety Approvals | |||
Safety Agency / Mark | Lighting | Medical(Meet) | ITE(Meet) |
CB | IEC61347 | IEC60601-1 | IEC60950-1 |
ANSI/AAMI ES60601-1 | - | ||
UL | UL 8750 | CAN/CSA-C22.2 NO. 60601-1 | |
EN 61347 | EN60601-1 | EN60950-1 | |
TUV | - | - | GB4943.1(For Class I only) |
CE | EN 61347 | - | - |
CCC | - | - | J60950-1(For Class I only) |